무하마드하룬
                     (Haroon Muhmmad)
                     1
                     변현우
                     (Hyun-Woo Byun)
                     2
                     이범식
                     (Bum-Sik Lee)
                     3
                     김길희
                     (Kil-Hee Kim)
                     4
                     이정윤
                     (Jung-Yoon Lee)
                     5†
               
                  - 
                           성균관대학교 건설환경시스템공학과 박사후연구원
                        (Postdoctoral Researcher, Department of Civil, Architectural, and Environmental System
                        Engineering, Sungkyunkwan University, Suwon 16419, Rep. of Korea
                        )
                        
 
                  - 
                           성균관대학교 건축토목공학과 학부과정
                        (Undergraduate Student, Department of Civil, Architectural Engineering, Sungkyunkwan
                        University, Suwon 16419, Rep. of Korea
                        )
                        
 
                  - 
                           LH공사 토지주택연구원 연구위원
                        (Senior Researcher, Land & Housing Institute, Korea Land & Housing Corporation, Daejeon
                        34047, Rep. of Korea
                        )
                        
 
                  - 
                           공주대학교 건축공학과 & 도시융합시스템공학과 교수
                        (Professor, Architectural Engineering & Urban systems Engineering, Kongju National
                        University, Cheonan 31080, Rep. of Korea
                        )
                        
 
                  - 
                           성균관대학교 건설환경공학부 교수
                        (Professor, School of Civil, Architectural Engineering and Landscape Architecture,
                        Sungkyunkwan University, 
                        Suwon 16419, Rep. of Korea)
                        
 
               
             
            
            
            Copyright © Korea Concrete Institute(KCI)
            
            
            
            
            
            
               
                  
키워드
               
               프리캐스트 콘크리트, 모멘트 저항 골조, 반응수정계수
             
            
               
                  
Key words
               
               precast concrete, moment resisting frames, response modification/force reduction factor
             
            
          
         
            
                  1. Introduction
               
                  The precast construction has a great potential to help overcoming the construction
                  industry from several challenges such as aging infrastructures, reduced population
                  and labor, high construction cost etc. The cost effectiveness and high-quality construction
                  have resulted in its widespread use, including the countries with high seismicity
                  (Kurama et al. 2018)(22). The construction industry in Korea is also adopting new trends of pre-fabrication
                  through industrial automation with reduced manpower and improved construction quality
                  and efficiency. However, the design standards practiced in precast construction industry
                  were initially developed for cast-in-place construction. Specially, regarding the
                  seismic design for the precast concrete structures, the Korean Standards (KCI 2017)(19), stipulates that the “precast special moment frames shall satisfy the relevant design
                  criteria”.
                  
               
               
                  However, the code does not specify the appropriate response modification factor, system
                  overstrength factor and displacement amplification factor etc. for precast concrete
                  frames as it does case of cast-in place concrete frames.
                  
               
               
                  The precast structures are developed by connecting pre- fabricated RC elements on
                  site, the performance of precast structures under seismic excitation is highly dependent
                  on the strength, stiffness, and deformation capacity of the connections. The connections
                  of precast structures usually become the weaker points, hence the poor seismic performance
                  of precast buildings in past earthquakes has often been attributed to poorly designed
                  and built connections (FIB 2003)(16). Several studies (Englekirk 1986; Hawkins and Englekirk 1987; Park 1995; ACI-ASCE
                  2001)(4,13,28) emphasized on special attention to the connections of the precast concrete structures
                  for safe and economical seismic design. Seo and Lee (1999)(32), Lee et al. (2009)(23) and Choi et al. (2010)(10) conducted experiments on various types of joints to evaluate the structural performance
                  of the connections of precast concrete frames.
                  
               
               
                  The seismic performance of precast structural systems and elements including connections,
                  have actively been investigated in different parts of the world. Specially the research
                  efforts under the US-Japan cooperative research program on precast seismic structural
                  systems (PRESSS) provided a base for several seismic design guidelines (Priestley
                  1991)(29). Restrepo et al. (1995)(30) tested six types of sub assemblages of moment resisting frames located at the perimeter
                  of buildings. Connections between the prefabricated elements were realized at beam
                  midspan or at the beam-to-column joint region with cast in- place concrete.
                  
               
               
                  The experimental results showed that the connection details can be successfully designed
                  and constructed to emulate cast-in- place construction. In Europe, a collaborative
                  five-year research project called SAFECAST was conducted to study the behavior of
                  precast concrete buildings under earthquake loading. 
                  
               
               
                  In Korea, the guidelines for precast concrete building structure were first published
                  by the Architectural Institute of Korea (AIK 1992)(5). The code recommended that the seismic analysis of the precast concrete members shall
                  be carried out with reduced modulus of elasticity (1/4 of the general concrete) considering
                  influence of the weaker performance of precast member joints. Additionally, the code
                  suggested to use a response correction factor of 3.0, 4.5, 4.0 or 5.0 for the bearing
                  wall structural system, moment resistance frame, and dual precast structural systems,
                  respectively. On the other hand, in the KCI (2017)(19), moments frames are classified into ordinary, intermediate, and special moment frames
                  for cast-in place RC structures, but the code doesn’t include any specifications for
                  seismic design of precast moment frames. Similarly, the Building Structural Standards
                  (KBC 2016)(6) also doesn’t recommend any seismic design guidelines for precast concrete structures,
                  which causes difficulties for the practicing engineers. The current ACI 318-19 (ACI
                  Committee 318 2019)(1) standards stipulates the details of the connections for precast special moment frames,
                  but no special rules are set for precast intermediate moment frames. Other guideline
                  on precast concrete structures (ACI T1 2001, 2003; ACI-ASCE 2001)(2,3,4) allow the use of the similar seismic coefficients for precast concrete structure with similar performances to that of the cast-in-place
                  concrete structure. The basic concepts of seismic design standards practiced in Korea
                  are similar to the ACI 318-19 (ACI Committee 318 2019)(1) standard, but there are few regulations that can actually review the performance
                  of precast concrete structures. Therefore, if the concept of seismic design for precast
                  concrete based on ACI 318-19 (2019)(1) is introduced in the Korean Building Code AIK (2016)(6), a separate restriction condition is required to ensure safety. Therefore, in this
                  study, the performance of the connection between the precast concrete intermediate
                  moment frame and the special moment frame was examined by adjusting the seismic load
                  size of the design load combination. 
                  
               
               
                  Although, the design codes  allow emulative connections for precast concrete structures
                  which can be simulated as equivalent cast-in-place monolithic connections. However,
                  studies (Khoo et al. 2006; Saghi and Shariatmadar 2016)(20,31) suggest that due to difficulties in construction process, the precast joints can
                  hardly achieve strength and stiffness similar to cast-in-place monolithic connections
                  and under seismic events substantial inelastic deformations are noticed in precast
                  connection regions. Considering such strength, deformation and energy dissipation
                  capacity reduction of precast connections compared to cast-in- place monolithic joints,
                  the RC frames with different levels of deformation capacities were analyzed, in this
                  study. The analyses were conducted first on two RC intermediate moment resisting plane
                  frames without considering the performance reduction due to precast construction in
                  order to set a base for further analysis. In the second stage, the RC frames with
                  reduced ultimate strength and deformation capacity were considered for analysis so
                  called the potential performance reduction in precast concrete frames connection can
                  be accounted for. The two frames with reduced performance had deformation capacities
                  equal to 75 % and 50 % of those for the initial frame based on the FEMA 356 (FEMA
                  2000)(15). Finally the response modification factors for the selected structures were calculated
                  using the method suggested in ATC-19 (1995)(8) guidelines.
                  
               
             
            
                  2. Response Modification Factor
               
                  The conventional force-based design approaches are suitable for designing the structures
                  with permanently applied actions. The current seismic design procedures follow the
                  similar design approach, while keeping allowance for the inelastic deformations utilized
                  to absorb seismic energy which leads to reduction in the design level forces. These
                  codes carry out this design process by allowing the use of a response modification
                  or force reduction factor, hereafter called R-factor, to reduce the elastic shear
                  force demand to the design level shear force. The R-factor accounts for several important
                  parameter such as material and system over- strength, seismic energy absorption and
                  dissipation, indeterminacy of structural systems to redistribute seismic forces from highly deformed regions
                  to low deformed regions etc. This factor is quite unique for every structural system.
                  Therefore, for each structural system, a unique R-factor is needed and assigned for
                  calculating the design base shear. Fig. 1 shows the definitions given in ASCE 7 (ASCE 2002)(12) for response modification factor. If the structures are designed to remain within
                  the elastic range, the relationship between the base shear and roof displacement will
                  follow a linearly elastic response, as shown with dotted line in Fig. 1. However, the actual structural responses deviate from the linear elastic line after
                  a certain force-deformation level, depending on the material and system configurations.
                  When the base shear reaches a level slightly higher than the design base shear ($V_{d}$),
                  the inelastic deformations or the plastic hinges develop. The systems dissipate energy
                  through inelastic deformations until the base shear reaches a maximum value ($V_{\max}$). 
                  
               
               
                  In the design process, the elastic force demands are reduced to the design level force
                  by using the R-factor, which the seismic design guidelines justify by relying on the
                  reserve strength and ductility of the structural systems. The ATC-19 (1995)(8) suggests that the R-factor assigned to any structural system shall account for three
                  parameters; the strength, ductility and the system redundancy. The assigned R-factors
                  are determined by separately calculating the values of each component. However, studies
                  (Zafar 2010)(33) system redundancy can be considered as a parameter contributing to overstrength.
                  Adopting the similar approach, in this study, the response modification factor for
                  the precast concrete moment frames is calculated by accounting for the two parameters,
                  the ductility and over-strength. Thus, the definition of R-factor adopted in this
                  study is given as;
                  
               
               
                  
                  
                        
                        
Fig. 1. Definition of response modification factor
                      
               
               
                  
                  
                  
                  
                  
                  
               
               
                  where, $R_{u}$ is the parameter accounting for the ductility and $R_{o}$ factor considers
                  the system over-strength.
                  
               
               
                  The ductility factor reduces the elastic demand force ($V_{e}$) to the level of maximum
                  force ($V_{\max}$), which may be represented as follows;
                  
               
               
                  
                  
                  
                  
                  
                  
               
               
                  The ductility related factor ($R_{u}$) depends on the global ductility ($\mu$) of
                  the well-detailed structural systems where $\mu$ is the ratio of the maximum roof
                  displacement to the roof displacement at yield. Several methods (Newmark and Hall 1982; Krawinkler and Nassar 1992;
                  Miranda and Bertero 1994; Borzi and Elnashai 2000)(9,21,25,26) are developed to relate the ductility related factor ($R_{u}$) to the global structural
                  ductility demand factor ($\mu$). In this study, Newmark and Hall’s method (Newmark
                  and Hall 1982)(26) is adopted which is given as; 
                  
               
               
                  
                  
                  
                  
                  
                  
               
               
                  
                  
                  
                  
                  
                  
               
               
                  
                  
                  
                  
                  
                  
               
               
                  where, $T$ is the pre-yield vibration period of idealized single- degree of freedom
                  (SDOF) system. 
                  
               
               
                  On the other hand, the overstrength parameter ($R_{o}$) accounts for the material
                  as well as system overstrength resulting from factors such as low gravity load at
                  the time of seismic load application, use of strength reduction factors, higher actual
                  material strengths than the specified values, redundancy of the structural systems
                  etc. This parameter can be defined as the ratio of the maximum base shear ($V_{\max}$)
                  to the design level base shear ($V_{d}$) which is given as;
                  
               
               
                  
                  
                  
                  
                  
                  
               
             
            
                  3. Model Structures
               
                  In this study, the analytical models for the 8-story plane precast RC intermediate
                  moment resisting frames were developed using software program PERFORM-3D. PERFORM-3D
                  is specialized software package developed for the damage assessment, specifically
                  intended for performance-based seismic assessment of structures (Mamun and Saatcioglu
                  2017(24). The program allows monitoring the inelastic behavior of structural components with
                  different level of deformation. Since the precast structures are developed by connecting
                  pre-fabricated RC elements on site, the connections of such structures usually become
                  the weaker points. Although, the design codes (FEMA 1997; IBC 1997; ACI Committee
                  318 2019)(1,14,17) allow emulative connections for precast concrete structures which can be simulated
                  as equivalent cast-in-place monolithic connections. However, studies (Khoo et al.
                  2006; Saghi and Shariatmadar 2016)(20,31) suggest that due to difficulties in construction process, the precast joints can
                  hardly achieve strength and stiffness similar to cast-in-place monolithic connections
                  and under seismic events substantial inelastic deformations are noticed in precast
                  connection regions. In order to analyze the connection details, material model should
                  include bonding between concrete and reinforcement bars in the joint sections. But
                  bonding performance varies widely depending on the type of joints. So in this study,
                  analyzing structure model was taken into place to evaluate the overall performance
                  of the PC frame. Considering such strength, deformation and energy dissipation capacity
                  reduction of precast connections compared to cast-in-place monolithic joints, the
                  RC frames with different levels of deformation capacities were analyzed. The analyses
                  were conducted first on two RC intermediate moment resisting frames (X-X’ and Y-Y’
                  frames), selected from the 3-dimensional frame given in Fig. 2, without considering the performance reduction due to precast construction in order
                  to set a base for other analysis. This initial frame is represented as B-IMRF which
                  stands for “basic intermediate moment resisting frame”. In the second stage, the RC
                  frames with reduced ultimate strength and deformation capacity were considered for
                  analysis so called the potential performance reduction in precast concrete frames
                  connection can be accounted for. The model frames with reduced performance had strength
                  and deformation capacities equal to 75 % and 50 % of those for the basic frame based
                  on the FEMA 356 (FEMA 2000)(15). The models were named as 75B-IMRF and 50B-IMRF, where the numbers 75 and 50 represent
                  the percentage of strength and deformation considered.
                  
               
               
                  
                  
                        
                        
Fig. 2. Basic plan and elevations of selected frame for analysis
                      
               
               
                  The plan of the selected structures is given in Fig. 2(a). Two plane frames (Frame X-X’ and Y-Y’) where chosen for the analysis to assess the
                  performance of structure in X- and Y-directions. The selected plane frames had 5 bays
                  each with widths of 10.8 m and 8.4 m for X-X’ and Y-Y’ frames respectively. The reinforcement
                  arrangement and cross-sectional details of beams and columns are given in Table 1 and 2. The concrete compressive strength ($f_{c}'$) of 24 MPa and reinforcement yielding
                  strength ($f_{y}$) of 400 MPa and 500 MPa for D16 rebars and D19 and above were used,
                  respectively. The buildings were modelled as a bare frame, neglecting any possible
                  contributions from non-structural elements. The beams were modeled as FEMA beam concrete
                  type, with bi-linear force-deformation curve considering the strength loss and deformation
                  capacities based on the modelling parameters and numerical acceptance criteria for
                  nonlinear analysis defined in FEMA 356 (FEMA 2000)(15). The selected FEMA beams had symmetrical sections at the ends. The compound beam
                  elements were considered to be under equal and opposite moments at the ends resulting
                  from the self-weight and element load with an inflection point at the midspan. The
                  compound beams were divided into two segments, with each segment modelled as an inelastic
                  FEMA beam element. The width of beam integral with the attached column was modelled
                  as a rigid segment having 10 times more the rigidity of the beam element in order
                  consider a rigid beam-column joints. The columns were also modeled using FEMA concrete
                  column elements. Similar to the beam element, FEMA columns also comprised of two inelastic
                  columns segment. The force-deformation (moment-rotation) backbone curves for beams
                  and columns were developed based on the FEMA 356 guidelines (FEMA 2000)(15) as shown in the Fig. 3. The yielding and ultimate moment capacities were calculated using a sectional analysis
                  program and the rotation deformation/rotation capacities were calculated using the
                  code guidelines (FEMA 2000)(15) according to the sectional and material properties of the members. In order to account
                  for the reduction in the strength and deformation performance of RC precast moment
                  connections, the strength and deformation values were reduced by 75 % and 50 % of
                  the initial frames. 
                  
               
               
                  
                  
                  
                  
                        
                        
Table 1. Beam reinforcement details and cross-section properties
                     
                     
                        
                        
                        
                              
                                 
                                    | 
                                       
                                    			
                                     
                                    			
                                   | 
                                 
                                       
                                    			
                                     X-X’ Beams (G1) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     Y-Y’ Beams (G3) 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Ends 
                                    			
                                  | 
                                 
                                       
                                    			
                                     Mid 
                                    			
                                  | 
                                 
                                       
                                    			
                                     Ends 
                                    			
                                  | 
                                 
                                       
                                    			
                                     Mid 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Section 
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Size (mm) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     500×700 
                                    			
                                  | 
                                 
                                       
                                    			
                                     500×700 
                                    			
                                  | 
                                 
                                       
                                    			
                                     600×700 
                                    			
                                  | 
                                 
                                       
                                    			
                                     600×700 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Top rebar 
                                    			
                                  | 
                                 
                                       
                                    			
                                     8-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     3-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     12-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     4-D22 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Bottom rebar 
                                    			
                                  | 
                                 
                                       
                                    			
                                     3-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     5-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     4-D22 
                                    			
                                  | 
                                 
                                       
                                    			
                                     12-D22 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Hoop 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@300 
                                    			
                                  | 
                              
                           
                        
                     
                   
                  
               
               
                  
                  
                  
                  
                        
                        
Table 2. Column reinforcement details and cross-section properties
                     
                     
                        
                        
                        
                              
                                 
                                    | 
                                       
                                    			
                                     
                                    			
                                   | 
                                 
                                       
                                    			
                                     Inner columns (C1) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     Outer columns (C2) 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     1F 
                                    			
                                  | 
                                 
                                       
                                    			
                                     2-8F 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1-8F 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Section 
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                                 
                                       
                                    			
                                    
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Size (mm) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1,000×1,000 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1,000×1,000 
                                    			
                                  | 
                                 
                                       
                                    			
                                     900×900 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Main rebar 
                                    			
                                  | 
                                 
                                       
                                    			
                                     28-D25 
                                    			
                                  | 
                                 
                                       
                                    			
                                     20-D25 
                                    			
                                  | 
                                 
                                       
                                    			
                                     16-D25 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Hoop (ends) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@150 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     Hoop (mid) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@300 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@300 
                                    			
                                  | 
                                 
                                       
                                    			
                                     D10@300 
                                    			
                                  | 
                              
                           
                        
                     
                   
                  
               
               
                  
                  
                        
                        
Fig. 3. Adopted load-deformation relationship of FEMA beam/column elements of intermediate
                           moment resisting frame models
                        
                      
               
             
            
                  4. Nonlinear Static Pushover Analysis
               
                  
                  
                        
                        
Fig. 4. Base shear vs. Roof drift ratio of frame
                      
               
               
                  The nonlinear static analyses were conducted on the structural models discussed above
                  using PERFORM-3D. One of the important things to consider in the pushover analysis
                  is the selecting a load distribution pattern. The FEMA standards (FEMA 2000)(15) suggest to use uniform or triangularly distributed load pattern. The program PERFORM-3D
                  provides three options for pushover load patterns including; 1) distribution based
                  on nodal load pattern, 2) load distribution based on the masses and a specified displacement
                  variation over the structural height, and 3) distribution of loads based on the masses
                  and mode shapes of the structures (CSI 2006)(11). In this study, the pushover load distribution pattern based on the masses and mode
                  shapes was selected. Fig. 4(a) and Fig. 4(b) compare the results of the pushover analysis in terms of base shear vs. roof displacement
                  of the model frames X-X’ and Y-Y’, respectively. The maximum base shear of structure
                  B-IMRF in X-X’ and Y-Y’ direction was noticed to be 3,694 kN and 3,894 kN, respectively.
                  For frames 75B-IMRF and 50B-IMRF the base shear for X-X’ direction was 3,440 and 3,084
                  kN, while for Y-Y’ direction it was 3,545 kN and 3,083 kN, respectively. It can be
                  observed that with reducing the section strength as discussed above, the base shear
                  was decrease, whereas the ultimate roof deflections were increased. The bi-linearized
                  backbone curves of all analyzed frames are given in Fig. 5. 
                  
               
             
            
                  5. Calculation for Response Modification Factor
               
                  As discussed above the response modification factor is calculated in this study as
                  a product of factor accounting for structural ductility ($R_{u}$) and the system overstrength
                  ($R_{o}$). For calculating the ductility related factor Newmark and Hall’s approach
                  (Newmark and Hall 1982)(26) was used which involves the roof displacement ductility ratio ($\mu$) and the fundamental
                  period of vibration ($T$). The vibration period was calculated through code specified
                  formula, which was greater than 0.50 sec. The roof displacement ductility ratio ($\mu$)
                  was taken as the ratio of the ultimate roof displacement to the roof displacement
                  at idealized yielding. The idealized yielding displacement ($\Delta_{y}$), was determined
                  by using the method suggested by (Pan and Moehle 1989)(27), as shown in Fig. 3. In this method, a secant line was drawn to intersect the base shear-deflection response
                  curve at $0.75V_{\max}$ ($V_{\max}$is the base shear). The secant line was extended
                  to intersect a horizontal line corresponding to the maximum base shear, and then projected
                  on the horizontal axis in order to obtain the yield deflection ($\Delta_{y}$). While
                  the ultimate roof displacement capacity of the model structures was taken as the displacement
                  capacity corresponding to the life safety (LS) drift limit of structure. The displacement
                  capacity corresponding to the LS limit states was computed in accordance with the
                  FEMA 356 (FEMA 2000)(15), which is taken as 0.75 of the drift corresponding to the collapse prevention limit
                  state. Ultimate displacement capacity was divided to the yield displacement to calculate
                  the ductility ratio $\mu$, which in the present case is equal to the ductility factor
                  $R_{\mu}$. Finally, the response modification factor $R$ was quantified for all frames
                  in X-X’ and Y-Y’ direction by multiplying the ductility factor $R_{\mu}$ to the overstrength
                  factor $R_{s}$. The final value of R-factor for each frame was taken as average value
                  of response modification factor in both directions. The calculated seismic response
                  parameters are shown in Table 3.
                  
               
               
                  
                  
                        
                        
Fig. 5. Bilinearized backbone curve
                      
               
               
                  
                  
                  
                  
                        
                        
Table 3. Calculated response modification factors for the selected structures
                     
                     
                        
                        
                        
                              
                                 
                                    | 
                                       
                                    			
                                     Structure 
                                    			
                                  | 
                                 
                                       
                                    			
                                     $V_{\max}$ (kN) 
                                    			
                                  | 
                                 
                                       
                                    			
                                     $R_{u}$ 
                                    			
                                  | 
                                 
                                       
                                    			
                                     $R_{o}$ 
                                    			
                                  | 
                                 
                                       
                                    			
                                     $R$ 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     B-IMRF 
                                    			
                                  | 
                                 
                                       
                                    			
                                     3,694.01 
                                    			
                                  | 
                                 
                                       
                                    			
                                     4.0 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1.64 
                                    			
                                  | 
                                 
                                       
                                    			
                                     6.5 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     75B-IMRF 
                                    			
                                  | 
                                 
                                       
                                    			
                                     3,440.28 
                                    			
                                  | 
                                 
                                       
                                    			
                                     4.2 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1.52 
                                    			
                                  | 
                                 
                                       
                                    			
                                     6.3 
                                    			
                                  | 
                              
                              
                                    | 
                                       
                                    			
                                     50B-IMRF 
                                    			
                                  | 
                                 
                                       
                                    			
                                     3,084.05 
                                    			
                                  | 
                                 
                                       
                                    			
                                     4.0 
                                    			
                                  | 
                                 
                                       
                                    			
                                     1.37 
                                    			
                                  | 
                                 
                                       
                                    			
                                     5.4 
                                    			
                                  | 
                              
                           
                        
                     
                   
                  
               
               
                  The calculated $R$ factor for B-IMRF frame was found to be approximately 6.5. In case
                  of frames with reduced strength and deformation capacities, the calculated $R$ factor
                  was 6.3 in case of frame 75B-IMRF and 5.4 in case of frame 50B-IMRF. Table shows the
                  base shear at yield, maximum based shear, ductility related factor, overstrength factor
                  and the response modification factors for all the selected structures. 
                  
               
             
            
                  6. Conclusions
               
                  In this study, the response modification factor of precast RC moment resisting frame
                  was determined by analyzing RC frames with different strength and deformation capacities
                  through PERFORM-3D. The analyses were first conducted on the precast RC frame with
                  strength and deformation capacities equivalent to a monolithic cast-in place intermediate
                  moment. In next phase of analysis, the frames with reduced strength and deformation
                  capacities in accordance with FEMA 356 standards were investigated. The R-factor was
                  finally calculated by evaluating a ductility related factor and system overstrength
                  factor which accounts for material overstrength and redundancy of the structural system.
                  The calculated value of R-factor for frame B-IMRF, 75B-IMRF and 50B-IMRF were 6.5,
                  6.3 and 5.4, respectively.